Step | | Procedure & Parts & Tools |
1 |
|
LIFT THE RECOVERY TANK FROM THE MACHINE.
|
2 |
|
RAISE THE TANK COVER UP UNTIL IT POPS OFF MACHINE.
|
3 |
|
LOCATE THE 2 HOSES COMING UP THRU THE SOLUTION TANK. PULL THE 2 HOSES CUFFS OFF HOSES.
|
4 |
|
REMOVE THE 2 BOLTS IN THE BATTERY COMPARTMENT.
Torx T30 |
|
|
5 |
|
LOOSEN THE BOLT ON THE FRONT OF THE SOLUTION TANK.
Torx T30 |
|
|
6 |
|
REMOVE THE 2 SOLUTION TANK BOLTS ON EACH SIDE OF THE TANK.
Torx T30 |
|
|
7 |
|
PULL THE TANK UP TO RAISE IT.
|
8 |
|
TURN THE POWER ON AND THE SOLUTION ON.
|
9 |
|
CHECK THE HOSE CONNECTION ON THE FRONT AND THE BACK OF THE PUMP FOR LEAKS.
|
10 |
|
IF THE SOLUTION PUMP IS OKAY, REVERSE STEPS 1 THRU 7 TO REASSEMBLE THE MACHINE.
|